next up previous contents
Next: Cabs Up: Multiplicative Model Components Previous: Absori

            acisabs: Chandra ACIS q.e. decay

This model accounts for the decay in the ACIS quantum efficiency most likely caused by molecular contamination of the ACIS filters. The user needs to supply the number of days between Chandra launch and observation. The acisabs parameters related to the composition of the hydrocarbon  and the rate of decay should be frozen and not modified. The present version of acisabs is to be used for the analysis of bare ACIS I and ACIS S data. For the present version of acisabs one must use the standard qe file vN0003 instead of the optional vN0004 file.

Because of the present large uncertainty in the ACIS gain at energies  below 350eV we recommend that events in the 0—350eV range be ignored in the spectral analysis until the gain issue is resolved.

acisabs calculates the mass absorption coefficients of the contaminant from atomic scattering factor files provided at

http://www-cxro.lbl.gov/optical_constants/asf.html .

 

par1

 Days between Chandra launch and ACIS observation

par2

 Slope of linear quantum efficiency decay

par3

 Offset of linear quantum efficiency decay

par4

 Number of carbon atoms in hydrocarbon

par5

 Number of hydrogen atoms in hydrocarbon

par6

 Number of oxygen atoms in hydrocarbon

par7

 Number of nitrogen atoms in hydrocarbon


 

next up previous contents